Catalog
Inquiry
Contact
Precision Motorized Stages

AZ5008 - Precision

AZ5008 - Precision

Guide-Crossed-roller Guide, In structure, V-groove and crossed roller acquire movement in high accuracy and capacity by linear transmission to act a high precision movement and load capacity performance.

Transmission Parts-Ball screw, It transmits through the ball involving in the locknut and screw to reach the accuracy and longer operation lifetime.

Material-Aluminum Alloy

  • Specifications
  • Technical Data
  • Image Download
Total of 1 models
Model AZ5008-A6PR-JD
Inquiry Add To Inquiry
Table Size (mm) 50*50mm
Travel Stroke (mm) ±4mm
Drive Type Φ6 ball screw, 1mm lead, 1:2 wedge lift
Rail Cross roller guided
Stage Material Aluminum Alloy
Surface Treatment Anodized natural color
Body weight 0.45kg
Coupling --
Accuracy Level P: Precision grade
Wiring Method R : Right wiring
Resolution(Pulse) (µm) 1µm (Full) / 0.5µm (Half)
Max. Speed(Full Step) (mm/sec) 5mm/sec
Positioning Precision (µm) 8um
Repeatability Precision(µm) ±0.5um
Load Capacity (Kgf) 3kgf
Missed Step (µm) 2um
Parallelism (µm) 20um
Dynamic Straightness (µm) 5um
Dynamic Parallelism (µm) 25um
Motor_Type/Shaft Numbers Five-phase stepper motor / ☐20 dual output shaft
Motor_Brand/Model Orientalmotor / PK513PB
Driver Brand/Model Orientalmotor / CVD Series - 5 Phase stepping motor (Additional options)
Connector_Stage Side Connector 15-Pin male end connetor D-SUB / 12-Pin male end connetor HRS
Connector_Controller Side Connector 15-Pin male end connetor D-SUB / 12-Pin male end connetor HRS (optional)
Sensor_Origin Sensor Photoelectric sensor GMT-sensor
Sensor_Limit Sensor Photoelectric sensor GMT-sensor
Motor proximity sensor GMT sensor
Sensor_Power Voltage 24V±10%
Sensor_Control Output NPN open collector output under 24V 8mA
Sensor_Output Control Testing (sensing):output transistor OFF (closed)
Product Overview

*1 If you need left-side wiring or motor replacement, please contact sales
*2 The standard connector types of the product are D-SUB and HRS
*3 The length of the lead from the connector is about 26cm


Multi-point repeated positioning accuracy

♦   Accuracy measurement description

1. Unidirectional positioning accuracy: within the range of the predetermined detection stroke, starting from a starting position, moving and positioning in a certain direction sequentially, and detecting the actual the difference between the movement value and the target movement value, and the maximum error value is taken. This value is the unidirectional positioning accuracy.
2. Multi-point repeated positioning accuracy: within the range of the predetermined detection stroke, when the mechanical program is executed, the position accuracy obtained by repeatedly running the same program code degree. Calculate the position deviation that occurs when the same position is repeated back and forth, and obtain the deviation value between the two.

♦   Precision introduction

1. Design the GMT high-level precision inspection method to meet the precision requirements of fiber coupling and semiconductor manufacturing process.
2. The detection of GMT high-end precision linear slide module series adopts multi-point repeated measurement, that is, multi-point quantity measurement within a fixed stroke range (points the amount is increased or decreased according to the length of the stroke), and the actual change of the round-trip position error is recorded, in pursuit of high precision and repeatability.
3. Through the non-contact laser interferometer measurement, to ensure that the unidirectional positioning is within 10μm, and the multipoint repetitive positioning accuracy is within 1.5μm. If there is a need for higher precision and precision, please contact the regional sales/business team.


System Configuration Diagram

♦   For detailed specifications, please read the description for the stage and connecting cable.

♦   For selection of driver, please refer to the cross-reference table for the motor/driver of the standard motorized stage or the GMT motor and driver catalog.

♦   The most preferred driver is recommended to be specified by GMT as considerations. For different needs, please choose the suitable driver based on real functional needs.



Axis Definition

GMT has defined different axis as the following figuration according to the movement direction:

Horizontal movement direction is X and Y axis.

Vertical movement direction is Z axis.

Movement around X, Y, Z axis is defined to α axis, β axis, and θ axis.

Green arrows present the specified axis movement direction.

 

Motor/driver

 

Electrical specifications
Stepper Motor/Driver Specifications Comparison Table
Electric slide table and connecting cable
Introduction to Electromagnetic Brake Stepper Motors
Introduction to Feedback Stepper Motors
Linear sliding table detection method (Z-axis)

Model

AZ5008-A6PR-JD
Specifications
Table Size (mm)
Travel Stroke (mm)
Drive Type
Rail
Stage Material
Surface Treatment
Body weight
Coupling
Accuracy Level
Wiring Method
Resolution(Pulse) (µm)
Max. Speed(Full Step) (mm/sec)
Positioning Precision (µm)
Repeatability Precision(µm)
Load Capacity (Kgf)
Missed Step (µm)
Parallelism (µm)
Dynamic Straightness (µm)
Dynamic Parallelism (µm)
Motor_Type/Shaft Numbers
Motor_Brand/Model
Driver Brand/Model
Connector_Stage Side Connector
Connector_Controller Side Connector
Sensor_Origin Sensor
Sensor_Limit Sensor
Motor proximity sensor
Sensor_Power Voltage
Sensor_Control Output
Sensor_Output Control